Instructions

manual

In this Page, you will find a guide for installing DSC systems, operating instructions as and "Questions and Answers" related DSC-SODs:

PC 510PC 560PC 585PC 1550PC 1580PC 1565-2PPC 2525PC 2550PC 2585 PC 3000PC 4020 PC 6010 Power608Power832Power864  and PowerSeries PC1616, PC1832, and PC1864

You need to view or download your files Adobe Acrobat Reader!

–––––––––––––

PC 510 User Guide - [PDF File (265 KB)] 

Installation Guide

 

PC 560 User Guide - [PDF File (292 KB)] 

Installation Guide

 

PC 585 User Guide - [PDF File (229 KB)] 
Installation Guide

 

PC 1550 User Guide - [PDF File (273 KB)] 
Installation Guide

 

PC 1580 User Manual - [PDF File] 
Installation Guide

 

PC 1565-2P User Guide - [PDF File (238 KB)] 
Installation Guide

 

PC 2525 User Manual - [PDF File] 
Installation Guide

 

PC 2550 User Manual - [PDF File] 
Installation Guide

 

PC 2585 User Manual - [PDF File] 
Installation Guide

 

PC 3000 User Guide - [PDF File] 
Installation Guide

 

PC 4020 User Guide - [PDF File] 
Installation Guide

 

PC 6010 User Guide - [PDF File] 
Installation Guide

 

Power608 User Manual - [PDF File (221 KB)] 
Installation Guide

 

Power832 User Guide - [PDF File] 
Installation Guide

 

Power864 User Guide - [PDF File] 
Installation Guide

 

PowerSeries PC1616, PC1832, and PC1864 - installation guide

 

USER GUIDE

1. MAIN CODE - four-digit (1234 factory code). Required to change with new master code
turn on and off the system, and enter and change all codes and functions.

2. INSERTING THE SYSTEM UNDER PROTECTION

Before the system is switched on, all doors and windows must be closed and there should be no doors
movement in guarded areas. At the time of dialing the code, the green LED (Ready) must be lit. If you are
your code has been dialed correctly, the keypad starts counting the exit time and the red LED (Armed) lights up.
NOTE: If you have made an error while entering the code, the keypad sounds a short sound, then
press the (#) button and re-enter your code.

3. DISABLING THE SYSTEM

When entering the front door, the keypad starts to sound with continuous sound, which is a warning that
you must quickly enter your personal code. If the System (yellow LED) remains on after the system is turned off,
check with function (*) (2) or (*) (3).
NOTE: If you have made an error while entering the code, the keypad outputs a prolonged sound,
then press the (#) button and re-enter your code.

4. FUNCTIONS WITH (*)

(*) (1) - Bypass (off) of a security zone.

Example: (*) (1) (05) (06) (#) - zones 5th and 6th are excluded from the guard. The alarm system can be switched on
in the order specified in item 2.
When the alarm system is switched off, the bypass fails.

(*) (2) - Overview of problems.

Press the (*) (2) - The "Trouble" or "System" light will flash
problems will be shown with an indication of the respective zones:
Indicator 1 - required technician: press (1) to determine the specific problem:

(1) - Low battery;

(2) - Problem in the siren chain;

(3) - General system problem;

(4) - General system tamper;

(5) - Total system monitoring.
Indicator 2 - Lack of mains power;
Indicator 3 - Telephone Line Monitoring Problem;
Indicator 4 - Communication failure;
Indicator light 5 - Zone fault;
Indicator 6 - Tamper Zone;
Indicator light 7 - Low battery of device;
Indicator 8 - Incorrect system clock.
Press the (#) button to finish the check.

(*) (3) - Check the zone in which an alarm event occurred.

Press the (*) (3) - the LED on the working zone blinks
Press the (#) button to finish the check.
The LED will go off when you turn the system on again.

(*) (4) - Bell on the door.

Pressing (*) (4) switches on the door bell, if you repeat the same buttons, the bell is switched off.

(*) (5) - Change of access codes.

- change master code-press buttons (*) (5) (old master code) (40) (new master code) (#)
Example: (*) (5) (1234) (40) (2580) (#);
- change of additional code - (*) (5) (master code) (01 to 32) (four digits for code) (#)
Example: (*) (5) (1234) (01) (9876) (#) or example: (*) (5) (1234) (02) (6789) (#).
- delete additional code - (*) (5) (master code) (01 to 32) (*) (#).
Example: (*) (5) (1234) (02) (*) (#) - second code is deleted.

(*) (6) - Adjust the clock of the system.

- press buttons (*) (6) (master code) (1) (hour, minute) (month, date, year) (#)

Example: (*) (6) (1234) (1) (12; 05) (03; 29; 06) (#).

(*) (7) - Restoration of a fire zone.

When triggered in a fire zone, it remains open (lit) and needs to be restored to switch on
system. This is done by pressing buttons (*) (7) (1) or (2) - the fire zone is extinguished.

and

5. WATER ASSEMBLY BUTTON - If you press the (P) button and hold it more
for two seconds, the siren will not sound, but the system will send your signal to the monitoring center.

 

 

 

 

 

QUESTIONS AND ANSWERS [FAQ]

[Question]: What protection does the DSC provide?

[Reply]: 1. Local protection - sound and light signals, and when an alarm event rings the ones in them - telephone / GSM

2. When observing and guarding objects - the plants send immediately and automatically full information about the status of the sites under phone and / or radio and / or GPRS and / or GSM and / orinternet transmitters to the monitoring center.

 

[Question]: What information does the DSC transmit?

[Reply]alarm - Disturbance or fire in an area, specifying exactly in which area the event occurred

priority - fire reports, emergency medical help, and panic triggered by the keypad of the alarm station or an extra "panic" button to the three institutions

information about turning on and off the system - with which code and how many hours the system is activated or deactivated

service info for - power failure in the secured facility, weak battery of the plant, physical damage to the elements, the alarm system or the transmitter

the transmitters also send a broken line telephone message

video information - TV image for the state of the subject in case of a situation (alarm, priority, on and off)

 

[Bakers]: What are the benefits of DSC security systems?

[Reply]: Information from DSC signaling and fire alarm systems is automatically sent to the monitoring center.

- All the information from the secured site is sent directly to the stakeholders within a few seconds

- the stakeholders acquire a realistic picture of the behavior of the security and fire alarm systems of the guarded object

- continuous technical control over the system is ensured

- ensuring the confidentiality of the information transmitted

- Incoming information is printed on a printer

- Possibility to provide television surveillance over the subject and video recording of alarm situations

 

[Bakers]: What kinds of alarm events are there? What is their meaning?

[Reply]: 1. Alarm zone - trigger specific sensor:

– PIR sensor (triggered in motion)

- for glass (triggered by broken glass or similar sound)

- Magnetic sensor (triggered when opening a door or window)

shooter sensor (triggered by vibration)

2. Fire alarm - triggered by raising the temperature in the area of the fire detector, smoke in the room, at the sensors exposure to dusting and contamination

3. Fire alarm from keyboard  - Pressing a fire alarm key on the keypad is triggered

4. Panic alarm -  is triggered when pressed BPW (Radio Panic Button) - stationary or manual

5. Panic alarm from keypad - it is triggered by pressing a panic button on the keyboard

6.  Panic Alarm Force - sent on activation / deactivation of the system by a client at the intervention of another person. When entering a special code, the system is activated / deactivated while sending Panic Alarm

7. Whole object alarm -  sent by systems that are not DSC (other plants)

 

[Question]: What are the main duties of the client when working with the alarm system

[Reply]1. Test the system - the prevention of problems with the alarm system is carried out with regular inspection and maintenance. We recommend that you check your system monthly! The system test is done in several steps:

- Before carrying out any activity on the alarm system, please notify the SOD DSC monitoring center (tel: 052/635077 or 0886/444548)

- Perform the Siren / Accumulator test by pressing * 6 (master code) 4. The siren and the keypad will sound for 2 seconds and all the lights on the keypad will light up. Press # to exit the test.

- Activate each sensor individually, such as open the door / window or walk in the motion sensor perimeter (pay attention to objects in front of or around the sensor that may interfere with its normal operation). When activating the sensor, make sure that the zone light is on if you have an LED keypad or if the zone number is displayed if you have an LCD display on the keyboard.

- When you complete the system test, notify the monitoring center again and seek advice if you have found a malfunction.

Note: during a system test (and at any other time) attempts to open, remove or move sensors, the control panel, the radio transmitter and all peripheral modules on the alarm system are forbidden!

2. Radio Panic Button Test Button (if any)

- Before carrying out any activity on the alarm system, please notify the SOD DSC monitoring center (tel: 052/635077 or 0886/444548)

- Hold the remote control button for 3-4 seconds and wait for confirmation to receive the signal from the on duty (if a problem is detected, it will take the necessary action to remove it)

Note: In the event of an incorrect, accidental and frequent activation of the Radio Panic Button without notification to the monitoring center, a penalty is imposed on the Security Agreement!

3. Other obligations

- When the system is triggered by your fault, please notify the SOD DSC monitoring center (tel: 052/635077 or 0886/444548)